El HI83200 es uno de los fotómetros más versátiles del mercado. Un solo aparato mide hasta 44 métodos críticos para el análisis de calidad agua.
CARACTERÍSTICAS
| Prueba | Intervalo | Método | Código del reactivo |
| Ácido cianúrico | 0 a 80 mg/L (ppm) | Turbidimétrico | HI93722-01 |
| Alcalinidad | 0 a 500 mg/L (ppm) as CaCO₃ | Verde de bromocresol | HI93755-01 |
| Aluminio | 0.00 to 1.00 mg/L (ppm) | Aluminón | HI93712-01 |
| Amonio intervalo bajo | 0.00 a 10.00 mg/L (ppm) | Nessler | HI93715-01 |
| Amonio intervalo medio | 0.00 a 3.00 mg/L (ppm) | Nessler | HI93700-01
|
| Bromo | 0.00 a 8.00 mg/L (ppm) | DPD | HI93716-01
|
| Calcio | 0 a 400 mg/L (ppm) | Oxalato | HI937521-01** |
| Cloro*, libre | 0.00 a 2.50 mg/L (ppm) | DPD | HI93701-01 |
| Cloro*, total | 0.00 a 3.50 mg/L (ppm) | DPD | HI93711-01 |
| Cobre intervalo alto | 0 a 1000 μg/L | Bicinchoninato | HI95747-01 |
| Cobre intervalo bajo | 0.00 a 5.00 mg/L (ppm) | Bicinchoninato | HI93702-01 |
| Color del agua | 0 a 500 PCU | Platino cobalto colorimétrico | — |
| Cromo VI intervalo alto | 0 a 1000 μg/L | Difenilcarbohidracida | HI93723-01 |
| Cromo VI intervalo bajo | 0 a 300 μg/L | Difenilcarbohidracida | HI93749-01 |
| Dióxido de cloro | 0.00 a 2.00 mg/L (ppm) | Rojo de clorofenol | HI93738-01 |
| Dureza, calcio | 0.00 a 2.70 mg/L (ppm) (as CaCO₃) | Calmagita | HI93720-01 |
| Dureza, magnesio | 0.00 a 2.00 mg/L (ppm) (as CaCO₃) | Colorimétrico EDTA | HI93719-01 |
| Fluoruro | 0.00 a 2.00 mg/L (ppm) | SPANDS | HI93729-01 |
| Fosfato intervalo alto | 0.0 a 30.0 mg/L (ppm) | Ácido amino | HI93717-01 |
| Fosfato intervalo bajo | 0.00 a 2.50 mg/L (ppm) | Ácido ascórbico | HI93713-01 |
| Fósforo | 0.0 a 15.0 mg/L (ppm) | Ácido amino | HI93706-01 |
| Hidracina | 0 a 400 μg/L | p-Dimetilaminobenzaldehído | HI93704-01 |
| Hierro intervalo alto | 0.00 a 5.00 mg/L (ppm) | Fenantrolina | HI93721-01 |
| Hierro intervalo bajo | 0 a 400 μg/L | TPTZ | HI93746-01** |
| Magnesio | 0 a 150 mg/L (ppm) | Calmagita | HI937520-01** |
| Manganeso intervalo alto | 0.0 a 20.0 mg/L (ppm) | Periodato | HI93709-01 |
| Manganeso intervalo bajo | 0 a 300 μg/L | PAN | HI93748-01** |
| Molibdeno | 0.0 a 40.0 mg/L (ppm) | Ácido mercaptoacético | HI93730-01 |
| Níquel intervalo alto | 0.00 a 7.00 g/L (ppt) | Fotométrico | HI93726-01 |
| Níquel intervalo bajo | 0.000 a 1.000 mg/L (ppm) | PAN | HI93740-01** |
| Nitrato | 0.0 a 30.0 mg/L (ppm) | Reducción de cadmio | HI93728-01 |
| Nitrato intervalo alto | 0 a 150 mg/L (ppm) | Sulfato ferroso | HI93708-01 |
| Nitrato intervalo bajo | 0 .00 a 1.15 mg/L (ppm) | Diazotización | HI93707-01 |
| Oxígeno, disuelto (OD) | 0.0 a 10.0 mg/L (ppm) | Winkler | HI93732-01 |
| Ozono | 0.00 a 2.00 mg/L (ppm) | DPD | HI93757-01 |
| pH | 6.5 a 8.5 pH | Rojo de fenol | HI93710-01 |
| Plata | 0.000 a 1.000 mg/L (ppm) | PAN | HI93737-01** |
| Potasio intervalo alto | 20 a 200 mg/L (ppm) | Turbidimétrico tetrafenilborato | HI93750-01 |
| Potasio intervalo bajo | 10 a 100 mg/L (ppm) | Turbidimétrico tetrafenilborato | HI93750-01 |
| Potasio intervalo medio | 0.0 a 20.0 mg/L (ppm) | Turbidimétrico tetrafenilborato | HI93750-01 |
| Sílice | 0.00 a 2.00 mg/L (ppm) | Azul heteropoli | HI93705-01 |
| Sulfato | 0 a 100 mg/L (ppm) | Turbidimétrico | HI93751-01 |
| Yoduro | 0.0 a 12.5 mg/L (ppm) | DPD | HI93718-01 |
| Zinc | 0.00 a 3.00 mg/L (ppm) | Zincón | HI93731-01 |
| Información para ordenar | HI83200-01 (115V) incluye celdas de muestreo y tapaderas (4 c/u), kit de preparación de muestra, paño para limpiar celdas, botella de vidrio de 60 mL para análisis de oxígeno disuelto, tijeras, adaptador de corriente AC/DC, manual de instrucciones. | ||